For health care professionals in EUROPE excepted those practicing in France as the following pages are intended to all International health care professionals and are not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011 article 34. Other health care professionals should select their country in the top right corner of the website.
Please note that the following pages are exclusively reserved for health care professionals in countries with applicable health authority product registrations. To the extent this site contains information, reference guides and databases intended for use by licensed medical professionals, such materials are not intended to offer professional medical advice. Prior to use, please consult device labeling for prescriptive information and operating instructions.
The Dreamtome RX Cannulating Sphincterotome is preloaded with a Dreamwire™ High Performance Guidewire to facilitate efficient cannulation.
The Jagwire High Performance Guidewire has a 5cm hydrophilic tip to help facilitate selective cannulation and negotiation of difficult anatomy.
Side-loading Torque Device designed for effective guidewire tip manipulation.
- Engineered to facilitate deep cannulation of the common bile duct.
- The Endo-Glide™ Coating promotes smooth tracking and enhances tactile sensation.
- Kink-resistant, nitinol shaft engineered for wire control and manipulation capabilities.
The Dreamwire High Performance Guidewire has a 10cm hydrophilic Dream Tip™ End, designed for soft, smooth access. Its Endo-Glide™ Coating promotes smooth tracking and enhances tactile sensation.
Side-loading Torque Device designed for effective guidewire tip manipulation.
- Engineered to facilitate deep cannulation of the common bile duct.
- The Endo-Glide Coating promotes smooth tracking and enhances tactile sensation.
- Kink-resistant, nitinol shaft engineered for wire control and manipulation capabilities.
The NaviPro Hydrophilic Guidewire is a 100 percent hydrophilic guidewire designed for cannulation and smooth passage through tortuous anatomy.
Important Procedural Note:
- To activate the Hydrophilic coating, prior to removing the guidewire from its dispenser, inject a sterile saline solution into the luer lock hub using a syringe.
CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
ENDO-1495202-AA
Provides extra strength and stability during catheter placement and exchange during contralateral access and in carotid procedures.
The Hydra Jagwire Guidewire offers two tips on a single guidewire - a 10cm and a 5cm hydrophilic tip - giving physicians the ability to work with one or both. The 10cm hydrophilic Dream Tip™ End is designed for soft, smooth access. Its Endo-Glide™ Coating promotes smooth tracking and enhances tactile sensation.
Side-loading Torque Device designed for effective guidewire tip manipulation.
- Engineered to facilitate deep cannulation of the common bile duct.
- The Endo-Glide Coating promotes smooth tracking and enhances tactile sensation.
- Kink-resistant, nitinol shaft engineered for wire control and manipulation capabilities.
Device Features
- Controlled Steerability enhances positioning for ERCP cannulation and sphincterotomy. Steerability enables intraductal selective cannulation to aid in accessing the pancreaticobiliary tree.
- Handle Brake helps maintain catheter bow for all tip sizes and added control during sphincterotomy.
Jagtail™ Guidewire Extension
- Engineered to facilitate deep cannulation of the common bile duct.
The NovaGold High Performance Guidewire is intended for use in selective cannulation of the biliary ducts, including the common bile, pancreatic, cystic, right and left hepatic ducts, and to aid in the placement of diagnostic and therapeutic devices during endoscopic procedures.
- The Triton™ Alloy Core provides a durable wire for working with accessory devices. The stiffness of the wire makes it pushable yet flexible for loading and rail support through the scope to facilitate device exchange.
- The 6cm atraumatic tip provides flexibility needed to access the pancreatico-biliary system.
- The radiopaque guidewire tip is designed to help confirm location within the duct under fluoroscopy.
Device Features
- Center Guidewire Lumen design allows the guidewire to extend from the center of the sphincterotome to aid in positioning and facilitates wire-guided cannulation. Center Injection Lumen design allows injection of contrast to exit from the center of the catheter enabling delivery of contrast to the intended duct.
- Controlled Steerability enhances positioning for ERCP cannulation and sphincterotomy. Steerability enables intraductal selective cannulation to aid in accessing the pancreaticobiliary tree.
- Handle Brake helps maintain catheter bow for all tip sizes and added control during sphincterotomy.
The NaviPro Hydrophilic Guidewire is a 100 percent hydrophilic guidewire designed for cannulation and smooth passage through tortuous anatomy.
NaviPro Hydrophilic Guidewires are available in two tip configurations to facilitate cannulation of the biliary ducts in a variety of therapeutic cases.
Important Procedural Note:
- To activate the Hydrophilic coating, prior to removing the guidewire from its dispenser, inject a sterile saline solution into the luer lock hub using a syringe.
The Jagwire High Performance Guidewire has a 5cm hydrophilic tip to help facilitate selective cannulation and negotiation of difficult anatomy.
Side-loading Torque Device designed for effective guidewire tip manipulation.
- Engineered to facilitate deep cannulation of the common bile duct.
- The Endo-Glide™ Coating promotes smooth tracking and enhances tactile sensation.
- Kink-resistant, nitinol shaft engineered for wire control and manipulation capabilities.
The Dreamtome RX Cannulating Sphincterotome is preloaded with a Dreamwire™ High Performance Guidewire to facilitate efficient cannulation.
- A center-lumen design that is the result of DirecTip Technology. The center lumen allows the guidewire to extend from the center of the sphincterotome to aid in positioning and facilitates wireguided cannulation
- DirecTip Technology enables the guidewire and contrast to be directed into the duct from the center of the tip, helping the physician inject contrast into the intended duct. The tapered tip enables placement into small or tight orifices.
Device Features
- Center Guidewire Lumen design allows the guidewire to extend from the center of the sphincterotome to aid in positioning and facilitates wire-guided cannulation. Center Injection Lumen design allows injection of contrast to exit from the center of the catheter enabling delivery of contrast to the intended duct.
- Controlled Steerability enhances positioning for ERCP cannulation and sphincterotomy. Steerability enables intraductal selective cannulation to aid in accessing the pancreaticobiliary tree.
- Handle Brake helps maintain catheter bow for all tip sizes and added control during sphincterotomy.
- Direct Wire Technology™ is designed for flexibility and responsiveness to aid in precise sphincterotomy
-
Tip orientation and cut-wire positioning capabilities developed to facilitate cannulation
-
Option to transition from over-the-wire to short-wire ERCP technique without removing devices from the endoscope
-
TRUEtome™ Preloaded with Jagwire High Performance Guidewire
-
The Jagwire High Performance Guidewire has a 5cm hydrophilic tip to help facilitate selective cannulation and negotiation of difficult anatomy.
- Designed for performance, the TRUEtome Cannulating Sphincterotome is for the physician who prefers over-the-wire devices and values having options when it comes to guidewire selection.
TRUEtome™ Preloaded with Jagwire High Performance Guidewire. The TRUEtome Cannulating Sphincterotome is for physicians who prefer using an over-the-wire guidewire for ERCP. The Jagwire High Performance Guidewire has a 5cm hydrophilic tip to help facilitate selective cannulation and negotiation of difficult anatomy.
TRUEtome™ Preloaded with Hydra Jagwire™ High Performance Guidewire. The TRUEtome Cannulating Sphincterotome is for physicians who prefer using an over-the-wire guidewire for ERCP. The Hydra Jagwire Guidewire offers two tips on a single guidewire - a 10cm and a 5cm hydrophilic tip - giving physicians the ability to work with one or both. The 10cm hydrophilic Dream Tip™ End is designed for soft, smooth access. Its Endo-Glide™ Coating promotes smooth tracking and enhances tactile sensation..
TRUEtome™ Preloaded with Dreamwire™ High Performance Guidewire. The TRUEtome Cannulating Sphincterotome is for physicians who prefer using over-the-wire guidewire for ERCP. The Dreamwire High Performance Guidewire has a 10cm hydrophilic Dream Tip™ End, designed for soft, smooth access. Its Endo-Glide™ Coating promotes smooth tracking and enhances tactile sensation.
The Jagtome RX Cannulating Sphincterotome is preloaded with a Jagwire™ High Performance Guidewire to facilitate efficient cannulation. Facilitates a smooth transition from over-thewire to short-wire ERCP technique without removing devices from the endoscope
Guidewire Tip Technology
Engineered for excellent tactile feedback
- 5cm hydrophilic tip is designed to facilitate duct access
- Designed to reduce tip impaction trauma during papillary cannulation
- Tungsten-filled tips provide fluoroscopic visualization to help confirm access during device exchange
Guidewire Design
Insulated guidewire may be left in place during sphincterotomy
- Kink-resistant, nitinol shaft engineered for wire control and manipulation capabilities
- Striped movement markers designed to indicate wire positioning during wire advancement and device exchange
- Endoglide™ Coating intended to promote smooth tracking and enhance tactile sensation
The Jagtome RX Cannulating Sphincterotome is preloaded with a Jagwire™ High Performance Guidewire to facilitate efficient cannulation. Facilitates a smooth transition from over-thewire to short-wire ERCP technique without removing devices from the endoscope
Guidewire Tip Technology
Engineered for excellent tactile feedback
- 5cm hydrophilic tip is designed to facilitate duct access
- Designed to reduce tip impaction trauma during papillary cannulation
- Tungsten-filled tips provide fluoroscopic visualization to help confirm access during device exchange
Guidewire Design
Insulated guidewire may be left in place during sphincterotomy
- Kink-resistant, nitinol shaft engineered for wire control and manipulation capabilities
- Striped movement markers designed to indicate wire positioning during wire advancement and device exchange
- Endoglide™ Coating intended to promote smooth tracking and enhance tactile sensation
Merging Lumen Technology™
Proximal lumens merge into a single distal lumen on RX 44 Sphincterotome
- Developed to facilitate contrast injection while maintaining guidewire access through open lumen technology
TRUEtome™ Preloaded with Jagwire Revolution High Performance Guidewire. The TRUEtome Cannulating Sphincterotome is for physicians who prefer using an over-the-wire guidewire for ERCP. The Jagwire Revolution High Performance Guidewire is a versatile .025" guidewire engineered to have stiffness and pushability that you would expect in our Jagwire .035" guidewire combined with both access and exchange characteristics to help improve cannulation success in challenging anatomy.
TRUEtome™ Preloaded with Jagwire Revolution High Performance Guidewire. The TRUEtome Cannulating Sphincterotome is for physicians who prefer using an over-the-wire guidewire for ERCP. The Jagwire Revolution High Performance Guidewire is a versatile .025" guidewire engineered to have stiffness and pushability that you would expect in our Jagwire .035" guidewire combined with both access and exchange characteristics to help improve cannulation success in challenging anatomy.
The Jagtome RX Cannulating Sphincterotome is preloaded with a Jagwire™ High Performance Guidewire to facilitate efficient cannulation. Facilitates a smooth transition from over-thewire to short-wire ERCP technique without removing devices from the endoscope
Guidewire Tip Technology
Engineered for excellent tactile feedback
- 5cm hydrophilic tip is designed to facilitate duct access
- Designed to reduce tip impaction trauma during papillary cannulation
- Tungsten-filled tips provide fluoroscopic visualization to help confirm access during device exchange
Guidewire Design
Insulated guidewire may be left in place during sphincterotomy
- Kink-resistant, nitinol shaft engineered for wire control and manipulation capabilities
- Striped movement markers designed to indicate wire positioning during wire advancement and device exchange
- Endoglide™ Coating intended to promote smooth tracking and enhance tactile sensation
Merging Lumen Technology™
Proximal lumens merge into a single distal lumen sphincterotome
- Developed to facilitate contrast injection while maintaining guidewire access through open lumen technology
The Hydratome RX Cannulating Sphincterotome is preloaded with a Hydra Jagwire™ High Performance Guidewire to facilitate efficient cannulation.
The Hydratome RX Cannulating Sphincterotome is preloaded with a Hydra Jagwire™ High Performance Guidewire to facilitate efficient cannulation.
DirecTip™ Technology
- The Hydratome RX 44 Cannulating Sphincterotome has a center-lumen design that is the result of DirecTip Technology. The center lumen allows the guidewire to extend from the center of the sphincterotome to aid in positioning and facilitates wireguided cannulation.
- DirecTip Technology enables the guidewire and contrast to be directed into the duct from the center of the tip, helping the physician inject contrast into the intended duct. The tapered tip enables placement into small or tight orifices.
The Jagtome Revolution RX Cannulating Sphincterotome is preloaded with a Jagwire Revolution High Performance Guidewire to facilitate efficient cannulation.
Jagwire Revolution High Performance Guidewire is a versatile .025” guidewire engineered to have the stiffness and pushability that you would expect in our Jagwire .035’’ guidewire combined with both access and exchange characteristics to help improve cannulation success in challenging anatomy.