text.skipToContent text.skipToNavigation
175 Products found
  • Wallstent PC Endoscopic Biliary Endoprosthesis
    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1528604-AA
  • Duodenal Bend Biliary Stent with Delivery System
    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1528706-AA
  • Uncovered RX Biliary Endoprosthesis Stent System
    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1528806-AA
  • Epic Biliary Stent

    Laser Cut Self-Expanding Metal Stent
    The Epic Biliary Endoscopic Stent System is indicated for the palliation of malignant neoplasms in the biliary tree. It may be used to palliate strictures caused by unresectable Bile Duct Cholangiocarcinoma. The Epic Biliary Stent was developed for physicians who prefer a laser cut stent.

    Optimization of Laser Cut Design

    • Minimal Foreshortening
      • Aid in placement
    • Low Profile 6Fr Catheter
      • Designed to help place the stent across tighter strictures
    • Up to 100mm Stent Length
      • May help to reduce the need for placement of additional stents
    • Tantalum Radiopaque Markers at the Distal and Proximal End of the Stent
      • Enhanced fluoroscopic visualization to aid in deployment precision
    • 220cm Catheter
      • Compatible with duodenoscopes for standard ERCP procedures and balloon enteroscopy-assisted ERCP scope

    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1503907-AA
  • Advanix Biliary Duodenal Bend Stent

    The Advanix Biliary Stent is specifically designed to maximize flow rate, improve deliverability of the stent and enhance procedural control and efficiency to improve patient outcome.

    Maximized Lumenal Integrity

    • Thin wall design for maximized inner diameter – full length of stent designed to maximize flow rates and help reduce clogging

    Improved Deliverability

    • Tapered stent tip design to improve pushability and help reduce risk of tissue trauma
    • RX System compatible to allow physician to secure guidewire access

    Enhanced Procedural Control and Efficiency

    • Ability to reposition stent to aid in accurate placement.
    • Black guide catheter with fluoroscopic marker; radiopaque stent with endoscopic marker
    • Highly visible guidewire exit port

    Scope Compatibility: 7Fr and 8.5Fr stents require a 3.2mm working channel; 10Fr stents require a 4.2mm working channel.

     

    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1478105-AA
  • Wallstent Uncovered Endoscopic Biliary Endoprosthesis
    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1528803-AA
  • Wallflex Biliary RX PC Stent System

    The WallFlex Biliary RX Stent technology is built on science and innovation to expand options for the treatment of biliary strictures.

    Pioneering Designs

    • Removability
      • The fully covered stent is indicated for indwell up to 12 months after placement in benign biliary strictures secondary to chronic pancreatitis.
    • Migration Resistance
      • Looped and flared stent ends are designed to help reduce the risk of tissue trauma and stent migration.
    • Tissue In-Growth Prevention
      • Closed cell construction and Permalume™ covered options designed to help resist tissue in-growth.1,2
    • Flexibility
      • Platinol™ Wire construction provides flexibility to help aid placement in tortuous anatomies.*
    • Radial Force
      • Radial force helps maintain stent patency and resist migration.
    * Flexibility varies by size of stent
     
    REFERENCES
    Moss A.; Morris E.; MacMathuna P.; Palliative biliary stents for obstructing pancreatic carcinoma. Cochrane Database Systematic Review, 25 Jan. 2006.
    Soderlund K., Linder S.; Covered metal versus plastic stents for malignant common bile duct stenosis: a prospective, randomized, controlled trial. Gastrointestinal Endoscopy, 2006; 63: 986-995

    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1527510-AA
  • Partially Covered RX Biliary Endoprosthesis Stent System
    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1528606-AA
  • RX Biliary
    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1523103-AA
  • WallFlex Biliary RX Uncovered Stent System
    The WallFlex Biliary RX Stent technology is built on science and innovation to expand options for the treatment of biliary strictures.
    • Migration Resistance
      • Looped and flared stent ends are designed to help reduce the risk of tissue trauma and stent migration.
    • Tissue In-Growth Prevention
      • Closed cell construction and Permalume™ covered options designed to help resist tissue in-growth.1,2
    • Flexibility
      • Platinol™ Wire construction provides flexibility to help aid placement in tortuous anatomies.*
    • Radial Force
      • Radial force helps maintain stent patency and resist migration.
    * Flexibility varies by size of stent
     
    REFERENCES
    Moss A.; Morris E.; MacMathuna P.; Palliative biliary stents for obstructing pancreatic carcinoma. Cochrane Database Systematic Review, 25 Jan. 2006.
    Soderlund K., Linder S.; Covered metal versus plastic stents for malignant common bile duct stenosis: a prospective, randomized, controlled trial. Gastrointestinal Endoscopy, 2006; 63: 986-995

    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1527411-AA
  • Advanix Biliary Center Bend Stent

    The Advanix Biliary Stent is specifically designed to maximize flow rate, improve deliverability of the stent and enhance procedural control and efficiency to improve patient outcome.

    Maximized Lumenal Integrity

    • Thin wall design for maximized inner diameter – full length of stent designed to maximize flow rates and help reduce clogging

    Improved Deliverability

    • Tapered stent tip design to improve pushability and help reduce risk of tissue trauma
    • RX System compatible to allow physician to secure guidewire access

    Enhanced Procedural Control and Efficiency

    • Ability to reposition stent to aid in accurate placement.
    • Black guide catheter with fluoroscopic marker; radiopaque stent with endoscopic marker
    • Highly visible guidewire exit port

    Scope Compatibility: 7Fr and 8.5Fr stents require a 3.2mm working channel; 10Fr stents require a 4.2mm working channel.

    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1478501-AA

     

  • Advanix Biliary Double Pigtail Stent

    The Advanix Biliary Stent is specifically designed to maximize flow rate, improve deliverability of the stent and enhance procedural control and efficiency to improve patient outcome.

    Maximized Lumenal Integrity

    • Thin wall design for maximized inner diameter – full length of stent designed to maximize flow rates and help reduce clogging

    Improved Deliverability

    • Tapered stent tip designed to improve pushability and help reduce risk of tissue trauma
    • RX System compatible to allow physician to secure guidewire access

    Enhanced Procedural Control and Efficiency

    • Ability to reposition stent to aid in accurate placement.
    • Black guide catheter with fluoroscopic marker; radiopaque stent with endoscopic marker
    • Highly visible guidewire exit port

    Scope Compatibility: 7Fr and 8.5Fr stents require a 3.2mm working channel; 10Fr stents require a 4.2mm working channel.

     

    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1478601-AA
  • Advanix Biliary Doudenal Bend Stent W/NaviFlex RX

    The Advanix Biliary Stent and NaviFlex™ RX Delivery System were specifically designed to maximize flow rate, improve deliverability of the stent and enhance procedural control and efficiency to improve patient outcomes.

    Maximized Lumenal Integrity

    • Thin wall design for maximized inner diameter – full length of stent designed to maximize flow rates and help reduce clogging

    Improved Deliverability

    • Reinforced delivery system designed to improve pushability and deliverability of stent through tight strictures and tortuous anatomies.
    • Tapered stent tip designed to improve pushability and help reduce risk of tissue trauma
    • RX System compatible to allow physician to secure guidewire access

    Enhanced Procedural Control and Efficiency

    • Ability to reposition stent to aid in accurate placement.
    • Black guide catheter with fluoroscopic marker; radiopaque stent with endoscopic marker
    • Highly visible guidewire exit port

    Scope Compatibility: 7Fr and 8.5Fr stents require a 3.2mm working channel; 10Fr stents require a 4.2mm working channel.


    Indications, Safety and Warnings

    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1442506-AA
  • Advanix Biliary Center Bend Stent W/NaviFlex RX

    The Advanix Biliary Stent and NaviFlex™ RX Delivery System were specifically designed to maximize flow rate, improve deliverability of the stent and enhance procedural control and efficiency to improve patient outcomes.

    Maximized Lumenal Integrity

    • Thin wall design for maximized inner diameter – full length of stent designed to maximize flow rates and help reduce clogging

    Improved Deliverability

    • Reinforced delivery system designed to improve pushability and deliverability of stent through tight strictures and tortuous anatomies.
    • Tapered stent tip designed to improve pushability and help reduce risk of tissue trauma
    • RX System compatible to allow physician to secure guidewire access

    Enhanced Procedural Control and Efficiency

    • Ability to reposition stent to aid in accurate placement.
    • Black guide catheter with fluoroscopic marker; radiopaque stent with endoscopic marker
    • Highly visible guidewire exit port

    Scope Compatibility: 7Fr and 8.5Fr stents require a 3.2mm working channel; 10Fr stents require a 4.2mm working channel.


    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1478602-AA
  • Wallflex Biliary RX Fully Covered RMV
    The WallFlex Biliary RX Stent technology is built on science and innovation to expand options for the treatment of biliary strictures.
    • Removability
      • The fully covered stent is indicated for indwell up to 12 months after placement in benign biliary strictures secondary to chronic pancreatitis.
    • Migration Resistance
      • Looped and flared stent ends are designed to help reduce the risk of tissue trauma and stent migration.
    • Tissue In-Growth Prevention
      • Closed cell construction and Permalume™ covered options designed to help resist tissue in-growth.1,2
    • Flexibility
      • Platinol™ Wire construction provides flexibility to help aid placement in tortuous anatomies.*
    • Radial Force
      • Radial force helps maintain stent patency and resist migration.
    * Flexibility varies by size of stent
    REFERENCES
    Moss A.; Morris E.; MacMathuna P.; Palliative biliary stents for obstructing pancreatic carcinoma. Cochrane Database Systematic Review, 25 Jan. 2006.
    Soderlund K., Linder S.; Covered metal versus plastic stents for malignant common bile duct stenosis: a prospective, randomized, controlled trial. Gastrointestinal Endoscopy, 2006; 63: 986-995

    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a physician.
    ENDO-1527412-AA